CR-P12-2

Part 1 Spring Cable Reel

Definition of our type                                                                                       

                                                                                                        KCRS1、KCRS11cable-reel-eng-p1-1    

l   Sheave Guide Chart                                                                                       l   Bracket Chart

CR-P1-3CR-P1-4

 

Specification and Dimension

cable-reel-eng-p1-3

KCRS2WKCRS3W                             KCRS4F、KCRS4W、KCRS5F、KCRS5T、KCRS6T

 

cable-reel-eng-p2-1

How to choose your type
1. Cable's diameter should be smaller than flange's.
2. Cable weight (per meter) X Length < Maximum reel torque
   Example:3.5mm/4C as Cable Dim shows 0.41 kg/m, 10m x 0.41kg/m = 4.1 kg<(7kg)
   Cross-refer the specification (P.5) find the choice is CRS 216W.

cable-reel-eng-p2-2

Reel mounted on the moving equipment will be an effort-saving way.

 

Design(Cross-refer Questionnaire) 

Definition

 

cable-reel-eng-p3-1

 

Example

cable-reel-eng-p3-2

 

Efficient Winding Force(kgf)   

            cable-reel-eng-p3-3   

Max Winding Force    cable-reel-eng-p3-4
Max Efficient Winding Force     Fe(kgf)=μ.F(kgf)     μ=0.7                                                                                    

When quantity of poles is over 4 or speed is over 40 m/min or other resistant cause occur, by all means add the buffer (reduce the μ Efficient Value)

 

Cable Dim

cable-reel-eng-p3-5

 

Spring cable reel installation

Step

1. Power-in terminal enter "D" slip ring until through "G" hollow axis, connected with "E" slip ring. (chart 1)

 cable-reel-eng-p4-1

A : 〇Cable Hole

B : Cable Fixed Flake

C : Cable End

D : Slip Ring Unit

E : Slip Ring

F : Carbon Brush Base

G : Axis Located Screw

H : Axis Located Screw

2. Cable pierces "A" hole 〇 from the inside of the roll plate and through "B" fixed point into "C" cable end. Connect the cable with carbon brush and

    arrange the cables. Lock the outside cap after connection. *To avoid cable hooking the screw parts, cables in the spring ring unit should be leaned

    aside as possible as you can. 

3. Roll all cables clockwise in the roll plate (chart 3), or handle the cable and move roll plate anti-clockwise till all cables completed. (chart 4)

4. Locate the cable reel.

cable-reel-eng-p4-2


5. Move the plate 2~3 cycles (snail shape spring will save the kinetic energy). Pull cable out through the sheave guide; make a trial run after connect

    power.

cable-reel-eng-p4-3

6. When the spring loses its elasticity, repeat the step 5.

7.

                 Moving cart roll horizontally                                             Moving cart on ground    

                                                                                                         

cable-reel-eng-p4-4 cable-reel-eng-p4-5

                        with sheave guide                                     (not recommended due to the addtional kinetic friction)
               (Recommended standard way)

 

Performance

                                                               -Spring Cable Reel-

CR-P5-1 CR-P5-2

For Glass Factory Vacuum Suction Cups                      For multi-function hoist equipment in precast Cement Factory

CR-P5-3 CR-P5-4

Avoid fixingthe electric door, only I-beam needed to suit        For Steel Factory: Moving Cart

CR-P5-5 CR-P5-6

For Gate Door Opening                                                For Civil Engineering 


Part 2 Motor Cable Reel

Definition of Our Type

cable-reel-eng-p6-1

cable-reel-eng-p6-2

 

T20 Motor Cable Reel

Application: Cable Dim 14mm2~38mm2, Horizontally Furl Length 50M~100M, Vertically Furl 30M. It is suitable for kinds of automatic assemble line. 

cable-reel-eng-p7-1

Specification

cable-reel-eng-p7-2

 Type Choice Reference (Horizontally Furl)

cable-reel-eng-p7-3

 

Type Choice Reference (Vertically Furl)

      T20H-1308~1314 Adopted When Vertically Furl Cable Dim 8mm2 x 4 pole~14mm2 x4 pole length in 30 M. 

cable-reel-eng-p8-1

cable-reel-eng-p8-2

T20、T20.1 Control Panel Explanation

cable-reel-eng-p8-3

 

T20.1 T40 Motor Cable Reel

Application: Cable Dim 22mm2~100mm2, Horizontally Furl Length 50M~160M, Vertically Furl 30M. It is suitable for flexible designand special format . 

Made-On--Demand

cable-reel-eng-p9-1

Specification

 cable-reel-eng-p9-2

Type Choice Reference (Horizontally Furl)

cable-reel-eng-p9-3

Type Choice Reference (Vertically Furl)

T20.1H-1522~1538 Adopted When Vertically Furl Cable Dim 22mm2 x 4 pole~38mm2 x 4 pole length in 30M.

cable-reel-eng-p10-1

 

cable-reel-eng-p10-2

T40 Control Panel Explanation

 cable-reel-eng-p10-3

 

 

M10 and M15 Motor Cable Reel

Application : Cable Dim 5.5mm2~14mm2Horizontally Furl Length 50M~100M.

For Low Noise And Thin Cable With Many Poles.

                       cable-reel-eng-p11-1

Specification

cable-reel-eng-p11-2

※Remark: KCRM-M15S-0914 Maximum Horizontally Furl Length is 100M.

cable-reel-eng-p11-3

 

cable-reel-eng-p11-4

 

 

M50 Motor Cable Reel

Maximum Furl Length 200M With Cable Dim 60mm2

     Maximum Furl Length 100M With Cable Dim 100mm2

Application: Heavy Duty And Thick Cable

CR-P12-1

 

CR-P12-2

 

                                                                  -Motor Cable Reel-

CR-P12-3 CR-P12-4

 CSBC Gantry Crane Motor Cable Reel                                Moving Cart Motor Cable Reel

 CR-P13-1  CR-P13-2

Tunnel Access 200 Ton Gantry Crane                            Fei-Tsui Reservoir Hydrology Measurment

CR-P13-3  CR-P13-4

Dragon Steel Factory Grab (Vertically 30 Meters)            For Agriculture: Watering Can

CR-P13-5  CR-P13-6

CSBC: For Moving Cart                                                    Civil Engineering: Cable In The Reinforced Concrete Box

 

Convenient Winder 

cable-reel-eng-p14-1

 

cable-reel-eng-p14-2